Abstract

Aim: The importance of the length and/or structure of fluorescently labeled PNA (peptide nucleic acid) probes for quantitative determination of oligodeoxynucleotides (ODNs) is demonstrated in human plasma using hybridization-based LC-fluorescence assays. The length of the PNA probes impacts the peak shape and chromatographic separation of the resulting PNA/ODN hybridization complexes and affects assay sensitivity, dynamic range and carryover. Methods: For quantitative determination of an 18-mer phosphodiester ODN (DNL1818) in human plasma, an assay utilizing an Atto dye-labeled 12-mer PNA probe provided a linear quantitation range of 0.1-50ng/ml with excellent accuracy and precision (within -5.3-7.73%). Conclusion: This method provides a convenient method for sensitive and specific quantification of ODNs in biological matrix with limited sample volume and no special extraction.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call