Abstract

Abstract The paper presents a study regarding the implementation of two representative grid synchronization methods, intended to be used in the control structure of a three phase switch mode voltage rectifier. The methods considered are the Synchronous Reference Frame Phase Locked Loop (SRF PLL) and the Double Synchronous Frame Phase Locked Loop (DSRF PLL), respectively. These synchronization methods have been compared on a real time development system type dSpace 1104 from the point of view of their performance in case of an unbalanced mains voltage system. Finally, the influence of the chosen grid synchronization method on the performance of a synchronous reference frame controlled three-phase switch mode voltage rectifier is studied by simulation, and better results are demonstrated to be provided by the use of the DSRF PLL.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.