Abstract

The number of primary arthroplasties is increasing and the proportion of revision arthroplasties is becoming increasingly more important. The need for standardized and guideline-based diagnostics for the safe detection of a periprosthetic joint infection (PJI) is becoming apparent. In the past 10 years various organizations have published definitions and diagnostic guidelines. The implementation of an inhouse standard test kit could help to simplify the process and could improve the diagnostic quality. In 2016 a test kit was compiled in a monocentric prospective study, taking the International Consensus Meeting (ICM) criteria 2014 and the Infectious Diseases Society of America (IDSA) criteria into account, which also fulfils the definitions of the ICM criteria 2018 and criteria of the European Bone and Joint Infection Society 2021. The test kit was implemented in the clinical setting of a special department for aseptic and septic revision arthroplasty. The usability and accuracy of the test kit were examined. The test kit was implemented using blood samples (leukocyte count; C‑reactive protein, CRP), samples for examining the synovial fluid (white blood cell count, PMN cell differentiation, microbiological culture for incubation over 14 days, alpha-defensin enzyme-linked immunosorbent assay, ELISA, leukocyte esterase test strips) together with information and request forms. Between April 2016 and February 2020 a total of 405 patients were investigated. Within 3 calendar years, the use of the test kit increased from 59% initially to 86%, and finally to 96% of cases in the third calendar year. The leukocyte esterase test strip was reliable in only 72%, due to undifferentiated readability or blood contamination. The costs increased by the only commercially available alpha-defensin ELISA test by approx. 52€ per puncture. The best individual test showed a sensitivity/specificity of 92.8%/95.2% with alpha-defensin. It was calculated which combinations showed a similar test quality and different combinations, such as CRP+ cell count+ microbiology showed a sensitivity/specificity both of around 90%. Metallosis is a challenge for preoperative PJI diagnostics. In a prospective study it was shown, that the implementation of the standardized test kit lead to a guideline based PJI diagnostic in all cases and thus to a significantly increase of the diagnostic quality. There is currently no single test that reliably excludes or proves an infection. The alpha-defensin laboratory ELISA test showed the best test accuracy, whereby the consideration of test combinations is obligatory and at the same time safe.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call