Abstract

The purpose of this prospective study was to measure and compare the accuracy and precision of dynamic navigation with freehand (FH) implant fixture placement. The authors hypothesized that the evaluated dynamic navigation system would have high accuracy and precision and would be superior to FH methods. The authors designed and implemented a prospective cohort study and enrolled patients who had implants placed from December 2014 through December 2016. The predictor variable was implant placement technique comparing fully guided (FG) and partially guided (PG) dynamic navigation with FH placement. The outcome variables were accuracy measured as deviation from the virtual plan, and precision was represented as the standard deviation of the measurements. Analysis of variance (ANOVA) was used to compare measurements. Virtual implant placement was compared with post-implant placement using mesh analysis. Deviations from the virtual plan were recorded for each implant for each surgeon. FH implant placement was evaluated by comparing a virtual plan with postoperative scans for patients who did not have the navigation system used for their implant placement. One-way ANOVA was performed to determine within-group and between-groups differences to determine whether there were meaningful differences among surgeons and methods (FG, PG, and FH) of placement. Prospective data from 478 patients involving 714 implants were evaluated. There were no demographic differences among surgeons. The sample size differed by the number of implants placed by each surgeon. Within each method group, the only difference among surgeons was angular deviation. All surgeons' data were combined. For FG navigation, the mean angular deviation was 2.97±2.09°, the mean global platform position deviation was 1.16±0.59mm, and the mean global apical position deviation was 1.29±0.65mm. For PG navigation, the mean angular deviation was 3.43±2.33°, the mean global platform position deviation was 1.31±0.68mm, and the mean global apical position deviation was 1.52±0.78mm. For FH placement, the mean angular deviation was 6.50±4.21°, the mean global platform position deviation was 1.78±0.77mm, and the mean global apical position deviation was 2.27±1.02mm. Differences in measurements comparing FG and PG navigation with FH indicated significantly less deviation from the virtual plan (P<.05) using navigation. Accuracy and precision for implant placement were achieved using dynamic navigation. The use of this type of method results in smaller deviations from the planned placement compared with FH approaches.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.