Abstract
BackgroundThere is a paucity of literature on manufacturer mismatch in reverse shoulder arthroplasty (RSA). It is unclear if use of different implant manufacturers for the glenoid side and the humeral side influences patient outcomes in primary RSA. We hypothesize that patients undergoing primary RSA with manufacturer mismatch such that humeral and glenoid components are from different manufacturers will not experience adverse outcomes when compared to a cohort of patients with humeral and glenoid components from the same manufacturer. MethodsBetween January 2016 and June 2020, all patients who had an RSA implanted by one fellowship-trained shoulder surgeon were considered potentially eligible for inclusion in this retrospective analysis of data prospectively collected during a multicenter study. The inclusion criteria were the following: primary RSAs implanted through a deltopectoral approach with glenoid and humeral components from different manufacturers, and complete data available at two years follow-up. The cohort was divided into a mismatch group and a control group, with the latter comprising patients having undergone RSA with components from the same manufacturer. ResultsFrom the initial cohort, 191 patients were available for the two-year clinical and radiological evaluation. Among these individuals were 60 men and 131 women, with a mean age of 74. The mismatch group comprised 39 patients and the control group included 152 patients. Baseline outcome scores of the mismatch and matched cohorts were similar regarding VAS (p= 0.220), SSV (p= 0.518), ASES (p=0.670), and Constant (p= 0.477) scores. Two-year postoperative outcome scores of the mismatched and matched cohorts were also similar regarding VAS (p=0.716), SSV (p=0.125), ASES (p=0.673), and Constant (p=0.607) scores. The complication rate and radiological complications were similar. ConclusionMixing of glenoid and humeral components from different manufacturers does not appear to affect patient outcomes in primary RSA at two years follow-up. The results may provide valuable information for orthopedic surgeons when selecting the appropriate implant components for RSA and help guide clinical decision-making for better patient outcomes. It appears reasonable to have manufacturer mismatch when appropriate matching of implant material and curvature at a given diameter is used.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.