Abstract

Several models were developed in the literatures for studying the system impedance characteristics during sub-synchronous oscillations (SSO). However, the doubly-fed induction generator (DFIG) impedance presents a 2 × 2 matrix with the frequency coupling component at the off-diagonal position, which increases the difficulty for analyzing the impedance characteristics of DFIG. The coupling effect in this case is caused by the asymmetric impedance characteristics of controllers, which are composed of voltage source converters (VSCs). Accordingly, simplifications are often conducted to decouple the impedance matrix into single sequences. Outer loop controller and phase-locked loop (PLL), which are often neglected in simplifications, are the main causes of the asymmetry of impedance matrix. Such simplifications could also hamper proper system stability analyses. In this paper, a comprehensive impedance model is proposed in which the outer loop controller, PLL, and grid-side controller (GSC) are all considered. The proposed comprehensive impedance model can provide exact stability data, in which stable boundaries for compensation level and transmission distances are presented. Furthermore, the proposed model is converted to simplified models in which the impacts of outer loop controller, PLL, GSC and coupling components on boundary stability of SSO are analyzed. The results are validated by time domain simulations and eigenvalue analyses, and deviations of the simplified models are analyzed for different operating parameters and conditions leading to simplifications.

Highlights

  • One of the critical subjects in the application of doublyfed induction generator (DFIG) is the sub-synchronous oscillation (SSO) caused by the interaction of DFIG with series compensation capacitors in power systems [1]–[4]

  • The coupling components could be caused by asymmetric characteristics of DFIG controllers which are composed of voltage source converters (VSCs)

  • It is difficult to obtain a comprehensive form of impedance model with coupling components, as impedance matrix will be very complex with the consideration of outer loop controller and phase-locked loop (PLL)

Read more

Summary

INTRODUCTION

One of the critical subjects in the application of doublyfed induction generator (DFIG) is the sub-synchronous oscillation (SSO) caused by the interaction of DFIG with series compensation capacitors in power systems [1]–[4]. In [7], outer loop controller and PLL are neglected, a DFIG and series-compensated network impedance model is derived, and the corresponding equivalent circuit is presented. It is difficult to obtain a comprehensive form of impedance model with coupling components, as impedance matrix will be very complex with the consideration of outer loop controller and PLL. In order to analysis the impacts of PLL, GSC, outer loop controller and coupling components on SSO analyses, we propose respective simplified impedance models and analyze the stable boundaries with different operation parameters, where proper conditions for simplifications are discussed. Neglecting outer loop controller and PLL will set the corresponding matrix in (5) and (6) to zero, in which case the impedance characteristic of DFIG will be decoupled.

COMPARISON OF IMPEDANCE AND EIGENVALUE ANALYSIS
STABLE BOUNDARIES CONSIDERING DIFFERENT IMPEDANCE MODELS
CONCLUSION

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.