Abstract
This paper describes the effect on over 3,000 sets of internal dose estimates of using photon Specific Absorbed Fractions (SAFs) calculated using two different types of phantoms, specifically the MIRD-type anthropomorphic phantom originally developed by Snyder and the new adult male voxel phantom, GOLEM, developed at GSF. The SAFs based on the MIRD-type phantom are currently used by the International Commission on Radiological Protection (ICRP) in internal dose calculations, but there are suggestions of moving towards SAFs generated from voxel phantoms, thus there is an interest in the potential differences in internal doses. Overall, it is found that some tissue doses calculated using the voxel phantoms can differ significantly from those of the MIRD-type phantom; however, the effective dose appears to be quite robust to changes in photon SAFs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.