The main purpose of this paper is to observe the effect PV variation of solar temperature and irradiance on different conditions and on the inverter output for a grid-connected system. Majorly temperature& solar irradiation effects the performance of a grid connected inverter, also on the photo-voltaic (PV) electric system. Thesimulation basedstudy was carried out in order toevaluate the variation of inverter output with the variation of solar temperature and irradiance with the variation in climate. The analysis of Grid-connected inverter and their performance at various seasons and conditions is investigated. Solar power plantfor a year. In solar power plant efficiency of inverter is also considered to calculate overall losses so, the inverterefficiency and plant performance are considered in this paper using MAT Lab software. In summer season the inverter performed efficiency is decreased because of peak temperature value and slightly increased with the increase in irradiance.