The risk of damage caused by reballing SnPb eutectic solder balls onto a commercial off-the-shelf (COTS) active flip chip with a ball grid array (BGA) of SAC305 was studied. The effects of reballing performed by five different reballers were examined and compared. The active flip chip device selected included manufacturer specified resistance between eight (8) differential port pairs. The path resistance between these pins following reballing, as compared to an unreballed device, was used to assess damage accumulation in the package. 2-dimensional x-ray microscopy, acoustic microscopy, and x-ray computer tomography were also used to characterize the effects of reballing. These studies indicated that no measureable damage was incurred by the reballing process, implying that reballed devices should function as well as non-reballed devices in the same application.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.