Abstract
BackgroundContinuous glucose monitoring (CGM) uses subcutaneous sensors and records the average interstitial sensor current every 5 min in the recorder; data are subsequently exported to a computer 4 to 7 days later when calibration with self-measured blood glucose is made retrospectively. How middle-aged and older patients perceive the added technology intervention is not clear.ObjectiveThe study aimed to understand the factors associated with the adoption of new technology in diabetes care, to understand the feelings and behaviors while using it, and to determine the changes in attitudes and behavior after completing the use of the new technology at the 3-month follow-up.MethodsMiddle-aged and older type 2 diabetes patients who had received professional continuous glucose monitoring (iPro 2 [Medtronic]) were invited for semistructured in-depth interviews on the day of the CGM sensor removal and at 3 months after CGM-based counseling. A phenomenography approach was used to analyze the interview data.ResultsA total of 20 type 2 diabetes patients (aged 53 to 72 years, 13 males and 7 females, 4 to 40 years duration of diabetes, mean glycated hemoglobin 8.54% [SD 0.71%]) completed 2 sections of semistructured in-depth interviews. Physician guidance and participant motivation toward problem solving were found to be factors associated with adoption of the device. Participants indicated that technology can be a reminder, a supervisor, and a visualizer of blood glucose, all of which are helpful for disease management. However, CGM is somewhat inconvenient, and some participants also reported that the provision of this new technology might be a hint of disease progression. There was a higher percentage of women compared with men who reported that CGM can be a reminder or a supervisor to help them with diet control.ConclusionsPhysician guidance and participants’ degree of motivation are keys to adopting new technology in the case of middle-aged and older adults. Although the CGM sensor may cause inconvenience to patients on their limited body movement when wearing the device, it is helpful for diet control and is an effective behavioral modification tool that offers support, especially in the case of women.
Highlights
2016 2017 2018 2019 2020 By sex Male Female
Data do not include Kinmen County and Lienchiang County before 1994.
2. Crude death rate is number of deaths per 100,000 population.
Summary
2016 2017 2018 2019 2020 By sex Male Female
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have