Abstract
Abstract Ultrasonic joining is a common industrial process. To build electrical connections in the electronics industry, uni-axial and torsional ultrasonic vibration have been used to join different types of workpieces for decades. Many influencing factors like ultrasonic power, bond normal force, bond duration and frequency are known to have a high impact on bond quality and reliability. Multi-dimensional bonding has been investigated in the past to increase ultrasonic power and consequently bond strength. This contribution is focused on the comparison of circular, multi-frequency planar and uniaxial vibration trajectories used for ultrasonic bonding of copper pins on copper substrate. Bond quality was analyzed by shear tests, scanning acoustic microscopy and interface cross-sections.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.