Abstract

Simulation of the dynamic behavior of mitral valve closure could improve clinical treatment by predicting surgical procedures outcome. We propose here a method to achieve this goal by using the immersed boundary method. In order to go towards patient-based simulation, we tailor our method to be adapted to a valve extracted from medical image data. It includes investigating segmentation process, smoothness of geometry, case setup and the shape of the left ventricle. We also study the influence of leaflet tissue anisotropy on the quality of the valve closure by comparing with an isotropic model. As part of the anisotropy analysis, we study the influence of the principal material direction by comparing methods to obtain them without dissection.Results show that our method can be scaled to various image-based data. We evaluate the mitral valve closure quality based on measuring bulging area, contact map, and flow rate. The results show also that the anisotropic material model more precisely represents the physiological characteristics of the valve tissue. Furthermore, results indicate that the orientation of the principal material direction plays a role in the effectiveness of the valve seal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.