Abstract
As part of the effort to understand oxy-fuel combustion with large CO2 dilution, we have measured shock tube ignition delay times for methane/O2/CO2 mixtures and hydrogen/O2/CO2 mixtures. Ignition delay times (IDT) were measured using sidewall pressure and OH* emission near 306 nm. IDT measurements were performed near 80 atm for 3.91% methane/9.92% oxygen/carbon dioxide mixtures and near 110 atm for 7.5% methane/15% oxygen/carbon dioxide mixtures. IDT measurements for 10% hydrogen/5% oxygen/carbon dioxide mixtures were also performed near 110 atm. IDT measurements were compared to several current mechanisms. Excellent agreement was seen between the ARAMCO and USC Mech 2 models and the data under the current operating conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.