Abstract

The presented paper shows the possibility of using holographic interferometry and hot‐wire anemometry in the research of heat transfer from impingement pulsatile flow. The intensity of heat transfer in the case of impingement flow is often measured with glue‐on heat flux sensors, or by indirect methods such as naphthalene sublimation. All these methods have a response time too long for measuring instant values of the heat transfer coefficient on a surface cooled/heated by impingement pulsatile flow. This shortcoming should be overcome by using CTA glue‐on probes or, preferably, by using optical methods such as holographic interferometry. It is necessary to employ a special holographic setup with double sensitivity instead of the commonly used Mach‐Zehnder type of holographic interferometer in order to attain the parameters sufficient for the studied case. This setup is not light efficient like the Mach‐Zehnder type but has double sensitivity. The results from the holographic interferometry experiments will be compared with the temperature field achieved by methods of hot‐wire anemometry.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.