Abstract

BackgroundFluorescence-guided visualization is a recently proposed technology in colorectal surgery. Possible uses include evaluating perfusion, navigating lymph nodes and searching for hepatic metastases and peritoneal spread. Despite the absence of high-level evidence, this technique has gained considerable popularity among colorectal surgeons due to its significant reliability, safety, ease of use and relatively low cost. However, the actual use of this technique in daily clinical practice has not been reported to date.MethodsThis survey was conducted on April 2020 among 44 centers dealing with colorectal diseases and participating in the Italian ColoRectal Anastomotic Leakage (iCral) study group. Surgeons were approximately equally divided based on geographical criteria from multiple Italian regions, with a large proportion based in public (89.1%) and nonacademic (75.7%) centers. They were invited to answer an online survey to snapshot their current behaviors regarding the use of fluorescence-guided visualization in colorectal surgery. Questions regarding technological availability, indications and techniques, personal approaches and feelings were collected in a 23-item questionnaire.ResultsQuestionnaire replies were received from 37 institutions and partially answered by 8, as this latter group of centers do not implement fluorescence technology (21.6%). Out of the remaining 29 centers (78,4%), fluorescence is utilized in all laparoscopic colorectal resections by 72.4% of surgeons and only for selected cases by the remaining 27.6%, while 62.1% of respondents do not use fluorescence in open surgery (unless the perfusion is macroscopically uncertain with the naked eye, in which case 41.4% of them do). The survey also suggests that there is no agreement on dilution, dosing and timing, as many different practices are adopted based on personal judgment. Only approximately half of the surgeons reported a reduced leak rate with fluorescence perfusion assessment, but 65.5% of them strongly believe that this technique will become a minimum requirement for colorectal surgery in the future.ConclusionThe survey confirms that fluorescence is becoming a widely used technique in colorectal surgery. However, both the indications and methods still vary considerably; furthermore, the surgeons' perceptions of the results are insufficient to consider this technology essential. This survey emphasizes the need for further research to reach recommendations based on solid scientific evidence.

Highlights

  • Fluorescence-guided visualization is a recently proposed technology in colorectal surgery

  • With particular reference to colorectal surgery, the main use of this technology is in real-time intraoperative angiography, which allows us to assess the perfusion of anastomotic stumps before and after anastomosis [3]

  • Another possible use is the search for superficial liver metastases [4] and small peritoneal metastases after intravenous injection performed at different times before surgery [5]; intratumor injection of Indocyanine green (ICG) allows visualization of the tumor itself and the draining of regional lymph nodes [6]

Read more

Summary

Introduction

Fluorescence-guided visualization is a recently proposed technology in colorectal surgery. Indocyanine green (ICG), approved for clinical use by the Food and Drug Administration (FDA) since 1959, is the most commonly used fluorescent probe It is a low-cost molecule that is easy to use, widely available and negligibly toxic [1]. With particular reference to colorectal surgery, the main use of this technology is in real-time intraoperative angiography, which allows us to assess the perfusion of anastomotic stumps before and after anastomosis [3] Another possible use is the search for superficial liver metastases [4] and small peritoneal metastases after intravenous injection performed at different times before surgery [5]; intratumor injection of ICG allows visualization of the tumor itself and the draining of regional lymph nodes [6]. The wide availability of this technology ( present in most new laparoscopic systems), its ease of use, the low cost of the molecule and the excellent visual yield have caused this technology to spread rapidly, despite the lack of robust scientific evidence from randomized controlled clinical trials

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call