Abstract
This review summarises the clinical knowledge of hypersensitivity pneumonitis in workers exposed to aerosols of metalworking fluid, reviewing published outbreaks and clinical cases. Metalworking fluid exposure has become the commonest recognised cause of occupational hypersensitivity pneumonitis, having been rare before 2000. There are many possible agents in the metalworking fluid which may be the cause of disease including bacteria, mycobacteria, fungae, biocides, emulsifiers, reodorants and dissolved chrome and cobalt. Causes are likely to be different in different outbreaks. Mycobacteria growing in the metalworking fluid have generated immune responses in some workers, but their role in disease causation is not yet established. Many outbreaks have been identified in large workplaces using common sumps. It is not possible to prevent microbial contamination of metalworking fluids in use. Disease prevention should focus on stopping inhalation of aerosols, particularly by re-engineering to remove recirculation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.