Abstract

Twenty-four laboratories participated in a collaborative study to validate a hydrophobic grid membrane filter (HGMF) method incorporating the use of 4-methylumbelliferyl-beta-D-glucuronide (MUG) for enumeration of total coliform and Escherichia coli bacteria in foods by comparing its performance against the AOAC 3-tube MPN method (46.013-46.016). Raw milk, raw ground poultry, whole egg powder, cheese powder, and ground black pepper were included in the study. The total coliform methods did not differ significantly, except that the 3-tube method detected a significantly higher level of total coliforms than did the HGMF method in the ground black pepper. Conversely, the HGMF/MUG E. coli method detected significantly higher numbers of E. coli present in the egg powder, cheese powder, and ground black pepper samples, while not differing significantly from the 3-tube method for the raw milk and raw ground poultry samples. The overall confirmation rate of MUG-positive colonies isolated using the HGMF method was 99.5%. The hydrophobic grid membrane filter/MUG method has been adopted official first action as an additional method to AOAC official final action method 46.030-46.034.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.