Abstract

Experimental and analytical studies on hydrogen-tritium isotope separation by a CECE process with a LPCE column have been carried out in order to apply it to the water detritiation system for fusion reactors. Kogel catalysts and Dixon gauze rings were mixed at a certain ratio and packed in the column in a random manner. Performance tests of tritium separation by the column of 1 m length and 2.5 cm I.D. were performed at 101 kPa and 343 K. The maximum value of the separation factor was 19200 when the flow rate of hydrogen gas was 5 L/min. The optimum value of catalyst packing ratio was obtained as 35 % by the analysis using the channeling stage model. The values of separation factors predicted by the model corresponded with measured ones very well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.