This paper focuses on hydrodynamic research aiming at the short-circuit evaluation of five different outlet configurations through the compartments of a mechanical flocculation unit of vertical shaft with mixing paddles at pilot scale. The tests were carried out with two, three and four compartments, variable and constant velocity gradients, including alternating senses of paddle rotation (clockwise in the first compartment, anticlockwise in the following one and so on). The research pointed out that the relevance of outlet configuration increases with the reduction of the number of compartments. In opposite, the velocity gradient and the sense of the paddle rotation seem less significant features. These results suggest the possibility of a viable increasing of performance, with low financial investments, mainly for flocculation units with three or two compartments installed in overloaded water treatment plants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.