Abstract
A three-dimensional dam-reservoir system under seismic load is analysed. The dam is assumed to be rigid. The reservoir is an infinite channel with semi-circular cross-section. The exact analytical solution, based on the assumption of potential fluid motion is presented, as well as numerical results for selected parameters. The most significant parameters are: the direction and frequency content of the seismic input; the radiation damping at the reservoir bottom; and the compressibility of the fluid. The response of the system depends strongly on the direction of the input ground motion. This is shown by the transfer functions as well as by the pressure time histories due to two earthquakes with different frequency content. The energy absorption at the reservoir bottom is important. A simple plane-wave model shows, that even for a rock foundation, the amount of transmitted energy can reach up to 80%. For comparison the case without bottom absorption is also shown. Compressbility has to be included to capture the resonance effects. The exact analytical solution is also used to verify numerical results obtained by a new method that combines a finite element model with a rigorous radiation boundary for the infinite channel in the time domain.