Abstract

Fouling in falling-film evaporators is a problem that reduces thermal efficiency and occurs due to the poor liquid distribution to the tubes and one of the consequences is the uncompleted wetting of the tube. This study proposes a design option based on the height of the feed hole and the geometry of the tube edge. The simulation was carried out with computational fluid dynamics using CFX Ansys 14.0 with multiphase and free surface models. The falling film was treated under a laminar regime as indicated by a regime flow. The results indicate that the proposed edges generate break-up in the film flow with rivulet formation, brink depth and counterflow from the air. The falling-films obtained showed flows in a transition regime, film thickness greater than that obtained experimentally and a falling-film wetting rate close to the experimental value. The simulations indicated that the greatest amount of wetted area on the wall is achieved with variable slope edges at a the low distributor plate height.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.