Abstract

Equations are developed for designing hydraulic rams of maximum thrust for a given external cylinder diameter. For push type rams, the optimum ratio of outside to inside wall diameter w is 1.554, and the maximum fluid pressure P to be used is 0.4142 times the allowable hoop stress ft in the cylinder. For pull type rams in which the allowable tensile stress fb in the pull bar (cylinder rod) and the allowable hoop stress ft in the cylinder wall are equal, w=1.414 and P=0.333 ft. When these allowable stresses are not equal, more complicated relationships exist and are discussed in the text.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.