Abstract
In this study, The System Advisor Model (SAM) simulation software has been used to analyze a Hybrid PV-Battery System in a residential cite in Iraq-Baghdad. The proposed system is 5kW which is affordable and applicable from the cost and required area points respectively. The monthly averaged electrical load is approximately calculated. The performance ratio for the system is 0.75 and about 6834 KWh is generated by the system per year. The results showed that the initial capital cost is 4,167.01$ which is returned after six years, LCOE Levelized cost of energy real is 7.66 ¢/kWh and Net present value is $4,649 made the system are very economical/no maintenance project and can be hooked to any the peak time load.