Abstract

Two chromatgraphic methods were developed for determination of Paracetamol (PCM) and Pamabrom (PAM) in presence of P-aminophenol (PAP) and Theophylline (THEO) as potential impurities of both drugs respectively. First method is HPTLC which depends on separation and quantitation of the studied drugs on aluminum plates pre-coated with silica gel 60 F254 as a stationary phase using chloroform:methanol:ethyl acetate:glacial acetic acid (8:0.8:0.6:0.2, v/v/v/v) as mobile phase followed by densitometric measurement of the bands at 254nm. Second method is RP-HPLC which comprises separation of the studied drugs on a Phenomenex C8 column by gradient elution using mobile phase consisting of sodium dihydrogen phosphate buffer (0.05M): methanol:acetonitrile (85:10:5, v/v/v) at a flow rate of 1mL/min for first 7.5min and (70:20:10, v/v/v) at a flow rate of 1.5mL/min for the next 5min. The proposed methods were successfully applied for determination of the potential impurities of PCM and PAM after resolving them from the pure drugs. The developed methods have been validated and proved to meet the requirements delineated by ICH guidelines with respect to linearity, accuracy, precision, specificity and robustness. The validated methods were successfully applied for determination of the studied drugs in their pharmaceutical formulation. The results were statistically compared to those obtained by the reported RP-HPLC method where no significant difference was found; indicating the ability of proposed methods to be used for routine quality control analysis of these drugs.