Abstract
A simple, rapid, and sensitive high-performance thin-layer chromatographic method for analysis of octachlorodipropyl ether (OCDPE) in insecticide formulations has been established and validated. Known amounts of analytical grade OCDPE and its emulsifiable concentrate (EC) or wettable powder (WP) formulations were characterized by HPTLC on silica gel with toluene-acetic acidwater 20:20:1 ( v/v ) as mobile phase; detection was by spraying with silver nitrate-2 m alcoholic potassium hydroxide as chromogenic reagent and exposure to UV light. The plates were evaluated densitometrically at 399 nm. The results indicated that the calibration plot for OCDPE was logarithmic in the range 0.2–5.0 μg per band, and the correlation coefficient for the calibration equation in this range was 0.99. Recoveries from laboratory-prepared test EC and WP formulations using this method were 98.5–103.9% and 95.3–104.3%, respectively, and the respective RSDs were 3.39–4.89% and 2.92–5.33%. The accuracy and precision of the method w...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.