Abstract

PurposeThis paper aims to investigate hot corrosion behaviour of different Cr3C2–NiCr coatings on boiler tube steel.Design/methodology/approachHigh velocity oxy fuel technique has been used to deposit different coatings on commercially available ASTM-SA213-T22 boiler tube steel. The hot corrosion studies have been performed in molten salt environment at 900°C temperature in silicon tube furnace in laboratory.FindingsThe results showed that uncoated superalloy suffered intense spalling and the weight change was massive during each cycle on studies of hot corrosion 900°C. The 100 per cent NiCr and 10 per cent (Cr3C2) – 90 per cent (NiCr) coatings provided better protection to T22 steel against the hot corrosion because of the formation of Ni and Cr3C2 layers.Originality/valueIn this research a variety of coatings have been used. This research work has been aimed to investigate the hot corrosion behavior of Boiler Steel b with different Cr3C2–NiCr coatings, under molten salt environment in Silicon tube furnace at 900°C, under cyclic conditions.