Abstract

Two rapid, specific, and sensitive high-pressure liquid chromatographic (HPLC) assays were developed for cloxacillin in serum and urine. A reversed-phase column (RP-8) was selected for use with two different sets of HPLC conditions and sample pretreatment procedures. Cloxacillin extraction efficiencies are reported from serum and urine. Equations are presented for linear relationships between peak height or peak area ratios of cloxacillin to nafcίllin (internal standard) and the cloxacillin concentration over a range of 0–80 μg/ml. The sensitivity limit of these assays was ~0.3 μg/ml of a standard solution for one method and 0.05 μg/ml for the other HPLC assay.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.