A simplified method for routine monitoring of 7 residual sulfonamides (SAs) (sulfadiazine (SDZ), sulfamerazine (SMR), sulfadimidine (SDD), sulfamonomethoxine (SMM), sulfamethoxazole (SMX), sulfadimethoxine (SDM), and sulfaquinoxaline (SQ)) in milk using high-performance liquid chromatography (HPLC) with a photodiode array detector is described. The spiked and blank samples were cleaned up by using an Ultrafree-MC/PL centrifugal ultrafiltration unit. For determination/identification, a Mightysil RP-4 GP column and a mobile phase of 25% (v/v) ethanol in water with a photodiode array detector were used. Average recoveries from milk samples spiked with 0.05, 0.1, 0.2, and 0.5 microg mL(-1) of each drug were >82%. The inter- and intra-assay variabilities were 2.0-3.1%. The practical detection limits for 7 SAs were 0.005-0.02 microg mL(-1). The total time and amount of solvent required for the analysis of one sample were <40 min and <6 mL of ethanol, respectively. No toxic solvents were used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.