Abstract

A sensitive reversed-phase high-performance liquid chromatographic method with ultraviolet detection was developed for the analysis of a new angiotensin II receptor antagonist, DuP 532 (L-694,492), in human plasma and urine. The analyte and internal standard are extracted from plasma and urine at a pH between 3.3 to 3.6 by liquid—liquid extraction and analyzed on a C 6 column with ultraviolet detection at 254 nm. The mobile phase is composed of acetonitrile and phosphate buffer at pH 2.5. The limits of quantification are 6 and 7.5 ng/ml for plasma and urine, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.