Abstract
Fluorescence molecular tomography in the near-infrared region is becoming a powerful modality for mapping the three-dimensional quantitative distributions of fluorochromes in live small animals. However, wider application of fluorescence molecular tomography still requires more accurate and stable reconstruction tools. We propose a shape-based reconstruction method that uses spherical harmonics parameterization, where fluorophores are assumed to be distributed as piecewise constants inside disjointed subdomains and the remaining background. The inverse problem is then formulated as a constrained nonlinear least-squares problem with respect to shape parameters, which decreases ill-posedness because of the significantly reduced number of unknowns. Since different shape parameters contribute differently to the boundary measurements, a two-step and modified block coordinate descent optimization algorithm is introduced to stabilize the reconstruction. We first evaluated our method using numerical simulations under various conditions for the noise level and fluorescent background; it showed significant superiority over conventional voxel-based methods in terms of the spatial resolution, reconstruction accuracy with regard to the morphology and intensity, and robustness against the initial estimated distribution. In our phantom experiment, our method again showed better spatial resolution and more accurate intensity reconstruction. Finally, the results of an in vivo experiment demonstrated its applicability to the imaging of mice.
Highlights
Near-infrared fluorescence molecular tomography (FMT) is used for the three-dimensional (3D) localization and quantification of fluorescent targets deep inside turbid tissue
Some devices for FMT are commercially available, the need for higher spatial resolution and more quantitative and reliable reconstruction hinders the wider application of this technique
High-density sampling [17], which increases the amount of boundary measurements, has proven effective, and several studies have focused on investigating the optimal source–detector configurations for different kinds of FMT imaging systems [18], [19]
Summary
Near-infrared fluorescence molecular tomography (FMT) is used for the three-dimensional (3D) localization and quantification of fluorescent targets deep inside turbid tissue. Additional prior information is generally applied through different regularization techniques. High-density sampling [17], which increases the amount of boundary measurements, has proven effective, and several studies have focused on investigating the optimal source–detector configurations for different kinds of FMT imaging systems [18], [19]. These advances have been critical to moving FMT from the laboratory to commercial applications, great challenges remain in order to obtain 3D fluorescence distributions stably and accurately
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.