Abstract
To reduce the loss of the dynamic range M/# of medium, we have proposed and demonstrated a high-pass filtering method for coaxial holographic data storage. Total exposure power decreased to 1/2 by removing the DC components of the Fourier-transformed signal and reference beams with a high-pass filter. Our proposed method can reduce the wasted dynamic range of medium. We evaluated the bit error rate of a high-pass-filtered signal beam to be 5.0×10-4 and that of an unfiltered signal beam to be 1.3×10-3. Thus, we confirmed that the quality of the signal beams without the DC component is comparable to that with the DC component. Next, we successfully recorded and reconstructed the filtered signal beam with the coaxial holographic configuration. The bit error rate of the retrieved signal beam was 1.4×10-3, showing the absence of degradation without the DC component of the retrieved signal beam. We also evaluated the shift selectivity improved from 5 to 2 µm by high-pass filtering.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.