Abstract

Recent advances in numerous biological applications have increased the accuracy of monitoring the level of biologically significant analytes in the human body to manage personal nutrition and physiological conditions. However, despite promising reports about costly wearable devices with high sensing performance, there has been a growing demand for inexpensive sensors that can quickly detect biological molecules. Herein, we present highly sensitive biosensors based on organic electrochemical transistors (OECTs), which are types of organic semiconductor-based sensors that operate consistently at low operating voltages in aqueous solutions. Instead of the gold or platinum electrode used in current electrochemical devices, poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) was used as both the channel and gate electrodes in the OECT. Additionally, to overcome the patterning resolution limitations of conventional solution processing, we confirmed that the irradiation of a high-power IR laser (λ = 1064 nm) onto the coated PEDOT:PSS film was able to produce spatially resolvable micropatterns in a digital-printing manner. The proposed patterning technique exhibits high suitability for the fabrication of all-PEDOT:PSS OECT devices. The device geometry was optimized by fine-tuning the gate area and the channel-to-gate distance. Consequently, the sensor for detecting ascorbic acid (vitamin C) concentrations in an electrolyte exhibited the best sensitivity of 125 μA dec-1 with a limit of detection of 1.3 μM, which is nearly 2 orders of magnitude higher than previous findings. Subsequently, an all-plastic flexible epidermal biosensor was established by transferring the patterned all-PEDOT:PSS OECT from a glass substrate to a PET substrate, taking full advantage of the flexibility of PEDOT:PSS. The prepared all-plastic sensor device is highly cost-effective and suitable for single-use applications because of its acceptable sensing performance and reliable signal for detecting vitamin C. Additionally, the epidermal sensor successfully obtained the temporal profile of vitamin C in the sweat of a human volunteer after the consumption of vitamin C drinks. We believe that the highly sensitive all-PEDOT:PSS OECT device fabricated using the accurate patterning process exhibits versatile potential as a low-cost and single-use biosensor for emerging bioelectronic applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.