Abstract

After confirming the basic characteristics of two types of metal gasket fittings, which are used in construction of ultrapure gas delivery systems for semiconductor manufacturing, it is noticed that the pipe usually twists at the time the fitting is tightened. This may be the possible cause of an external leak, therefore a twist leak test was undertaken to confirm the reliability of the seal during assembly. As a result, it was found that one type of fitting leaked and another type of fitting did not leak. This later type did not leak (leak rate is less than 2.98×10−16 Pa m3/s) even after 70° of twisting.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.