Abstract

The aim of this study was to evaluate agreement of measured thoracic aortic caliber in patients with aortic disease, using electrocardiographically-(ECG) and pulse-gated breath-hold noncontrast balanced steady-state free precession MRA (ECG-MRA, P-MRA) at 1.5 T, compared with ECG-gated computed tomographic angiography (CTA). Thirty-one patients underwent ECG-MRA, P-MRA, and CTA. Two readers independently measured aortic caliber in 7 segments, with agreement between techniques and readers evaluated. Image quality was qualitatively assessed. There was overall excellent agreement among ECG-MRA, P-MRA, and CTA for measured aortic caliber (Lin's concordance correlation coefficient ≥0.94, all comparisons); however, lower concordance was noted at the annulus (Lin's concordance correlation coefficient <0.6) at segmental assessment. There was excellent interreader agreement for aortic caliber for all 3 techniques (intraclass correlation coefficient >0.94). Image quality was poorer for both MRA techniques compared with CTA, particularly at the aortic root. Electrocardiographically-gated MRA and P-MRA at 1.5 T achieve comparable thoracic aortic measurements to gated CTA in clinical patients, despite inferior image quality.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call