Abstract
ObjectiveIn order to facilitate education for clinical users, performance aspects of the high-flow nasal cannula (HFNC) devices were evaluated in the present study. A multidimensional HFNC clinical evaluation system was established accordingly.Materials and MethodsClinical staff from Chinese hospitals were invited to participate in an online questionnaire survey. The questionnaire was mainly about the accuracy of temperature, flow rate, and oxygen concentration of HFNC, as well as its humidification capacity. We also investigated how the clinical staff of different professions made decisions on HFNC evaluation indicators. Based on the results of the questionnaire survey of clinicians with rich experience in using HFNC, the relative weights of temperature accuracy, flow velocity accuracy, oxygen concentration accuracy, and humidification ability of HFNC equipment were calculated by the AHP to establish a clinical evaluation system. Four kinds of common HFNC devices were tested and evaluated, and the clinical performance of the four kinds of HFNC devices was evaluated by the new scoring system.ResultsA total of 356 clinicians participated in and completed the questionnaire survey. To ensure the reliability of the HFNC evaluation system, we only adopted the questionnaire results of clinicians with rich experience in using HFNCs. Data from 247 questionnaires (80 doctors, 105 nurses, and 62 respiratory therapists [RTs]) were analyzed. A total of 174 participants used HFNC more than once a week; 88.71% of RTs used HFNC ≥ 1 score daily, 62.86% of nurses used HFNC ≥ 1 score daily, and 66.25% of doctors used HFNC ≥ 1 daily. There was no significant difference in the frequency of use between doctors and nurses. Finally, the relative weights of temperature accuracy (0.088), humidification capacity (0.206), flow velocity accuracy (0.311), and oxygen concentration accuracy (0.395) in the HFNC clinical evaluation system were obtained. The relative weights of clinicians with different occupations and the frequency of HFNC use were obtained. After testing four kinds of HFNC devices through the evaluation system, it was found that the four kinds of HFNC devices have different advantages in different clinical performances, and AiRVO2 has excellent performance with regard to temperature accuracy and humidification ability. HF-75A and NeoHiF-i7 are good at ensuring the stability of oxygen concentration and the accuracy of the flow velocity of the transported gas, while OH-80S is relatively stable in all aspects.ConclusionThe clinical evaluation system of HFNC is based on the weight of the experience of clinical personnel with different medical backgrounds. Although the existing practitioners have different educational backgrounds (academic qualifications, majors), our evaluation system can enhance clinical staff’s awareness of HFNC and further optimize the clinical use of HFNC.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.