Abstract

We present results of CCD radiation testing for a proposed Jovian mission. Samples of two candidate star tracker CCDs were irradiated with 10-MeV and 50-MeV electrons at Rensselaer Polytechnic Institute's Gaerttner LINAC. Differences in displacement damage effects on CCD parameters and star tracker performance are discussed for these two energies. Dark current, charge transfer efficiency (CTE), hot pixels, and flat-band voltage shifts are examined. Our electron data is compared to proton irradiation data taken by other experimenters. 10-MeV electron-induced transient data are also discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.