Abstract

Visible light photon counters (VLPCs) and solid-state photomultipliers (SSPMs) are high-efficiency single-photon detectors which have multi-photon counting capability. While both the VLPCs and the SSPMs have inferred internal quantum efficiencies above 93%, the actual measured values for both the detectors were in fact limited to less than 88%, attributed to in-coupling losses. We are currently improving this overall detection efficiency via a) custom anti-reflection coating the detectors and the in-coupling fibers, b) implementing a novel cryogenic design to reduce transmission losses and, c) using low-noise electronics to obtain a better signal-to-noise ratio.