Abstract

In this study, Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) coupled with chip-based direct-infusion nanoelectrospray ionization source (CBDInanoESI) in a negative ion mode is first employed to evaluate the effect of serum and its corresponding supernatant matrixes on the recoveries of serum free fatty acids (FFAs) based on spike-and-recovery experimental strategy by adding analytes along with analog internal standard (IS). The recoveries between serum (69.8-115.6%) and the supernatant (73.6-99.0%) matrixes are almost identical. Multiple point internal standard calibration curves between the concentration ratios of individual fatty acids to ISs, (C(17:1) as IS of C(16:1), C(18:3), C(18:2), or C(18:1) or C(21:0) as IS of C(20:4) or C(22:6)) versus their corresponding intensity ratios were constructed for C(16:1), C(18:3), C(18:2), C(18:1), C(20:4) and C(22:6), respectively, with correlation coefficients of greater than 0.99, lower limits of detection between 0.3 and 1.8 nM, and intra- and inter-day precision (relative standard deviations <18%), along with the linear dynamic range of three orders of magnitude. Sequentially, this advanced analytical platform was applied to perform simultaneous quantitative and qualitative analysis of multiple targets, e.g., serum supernatant unsaturated FFAs from 361 participants including 95 patients with pancreatic cancer (PC), 61 patients with pancreatitis and 205 healthy controls. Experimental results indicate that the levels of C(18:1), C(18:2), C(18:3), C(20:4) and C(22:6), as well as the level ratios of C(18:2)/C(18:1) and C(18:3)/C(18:1) of the PC patients were significantly decreased compared with those of healthy controls and the patients with pancreatitis (p < 0.01). It is worth noting that the ratio of C(18:2)/C(18:1), polyunsaturated fatty acids (PUFAs) (C(18:2), C(18:3), C(20:4), and C(22:6)), panel a (C(16:1), C(18:3), C(18:2), C(20:4) and C(22:6)) and panel b (C(18:2)/C(18:1) and C(18:3)/C(18:1)) performed excellent diagnostic ability, with an area under the receiver operating characteristic curve of ≥0.869, sensitivity of ≥85.7%, and specificity of ≥86.7% for differentiating the early stage PC from non-cancer subjects, which are greatly higher than those of clinically used serum biomarker CA 19-9. More importantly, this platform can also provide a fast and easy way to quantify the levels of FFAs in less than 30 s per sample.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.