Abstract

Optoretinography-the non-invasive, optical imaging of light-induced functional activity in the retina-stands to provide a critical biomarker for testing the safety and efficacy of new therapies as well as their rapid translation to the clinic. Optical phase change in response to light, as readily accessible in phase-resolved OCT, offers a path towards all-optical imaging of retinal function. However, typical human eye motion adversely affects phase stability. In addition, recording fast light-induced retinal events necessitates high-speed acquisition. Here, we introduce a high-speed line-scan spectral domain OCT with adaptive optics (AO), aimed at volumetric imaging and phase-resolved acquisition of retinal responses to light. By virtue of parallel acquisition of an entire retinal cross-section (B-scan) in a single high-speed camera frame, depth-resolved tomograms at speeds up to 16 kHz were achieved with high sensitivity and phase stability. To optimize spectral and spatial resolution, an anamorphic detection paradigm was introduced, enabling improved light collection efficiency and signal roll-off compared to traditional methods. The benefits in speed, resolution and sensitivity were exemplified in imaging nanometer-millisecond scale light-induced optical path length changes in cone photoreceptor outer segments. With 660 nm stimuli, individual cone responses readily segregated into three clusters, corresponding to long, middle, and short-wavelength cones. Recording such optoretinograms on spatial scales ranging from individual cones, to 100 µm-wide retinal patches offers a robust and sensitive biomarker for cone function in health and disease.

Highlights

  • Optoretinography, defined generally as the non-invasive, optical imaging of light-induced functional activity in the retina, has the potential to serve as an effective biomarker for retinal health and provide new insight into basic visual processes

  • A free space, multimodal, line-scan retinal imager consisting of a line-scan spectral domain optical coherence tomography (OCT) and line-scan ophthalmoscope (LSO) was designed and constructed

  • The basic principle behind the operation of an OCT in line-scan spectral domain configuration involves illuminating the sample with a line-field, achieved here with a cylindrical lens

Read more

Summary

Introduction

Optoretinography, defined generally as the non-invasive, optical imaging of light-induced functional activity in the retina, has the potential to serve as an effective biomarker for retinal health and provide new insight into basic visual processes. Electroretinography (ERG) is the current gold standard, despite the invasiveness of corneal electrodes and severe limits on spatial resolution and signal specificity of the elicited electrical activity[1,2]. Established electrophysiological tools such as patch clamp 3 and microelectrode arrays[4] are not yet feasible for study of retinal physiology in humans. The bright visible illumination required for fluorescence excitation inadvertently stimulates photoreceptors

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call