Abstract
Two open cavity in-fiber Fabry–Perot and Mach–Zehnder interferometers are fabricated and their liquid refractive index and temperature sensing characteristics are comparatively studied, respectively. In our experiments, for the Fabry–Perot interferometric sensor, its dip wavelength versus refractive index and temperature sensitivity is 50.001 nm/RIU (refractive index unit) for a refractive index range from 1.3351 to 1.3737 and 0.016 nm/deg, respectively. For the Mach–Zehnder with Fabry–Perot cavity sensor, its dip wavelength versus refractive index and temperature sensitivity is 587.089 nm/RIU at a 1.3331–1.3415 refractive index range, −647.755 nm/RIU at a 1.3415–1.3737 refractive index range, and 0.032 nm/deg, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.