Abstract
For the next-generation immersion lithography technology, there is a growing interest in the immersion fluids having a refractive index larger than 1.5 and low absorbance at 193nm wavelength. In this paper, we report our effort in identifying new immersion fluid candidates. The absolute refractive index values and thermo-optic coefficients, dn/dT, were measured with 1x10-4 and 1x10-5 accuracy respectively at 193nm wavelength. The results showed promising candidates having refractive index ranging from 1.5 to 1.65 with low absorbance at 193nm wavelength. Preliminary imaging results with a new immersion fluid gave good 65nm Line/Space patterns. However, the minimum exposure time of 20sec is about ten times as needed for water, indicating the need to further reduce the absorbance of the immersion fluid.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.