Abstract
AbstractWe have developed a sensor for the temperature measurement in the test section after the combustion chamber of an aero engine model by using direct absorption spectroscopy. Five distributed feedback diode lasers at near 1392, 1393, 1339, 1343, and 1469 nm are utilized as the light sources to detect H2O absorptions to improve the precision of temperature measurement combining with the Boltzmann plot method and the polynomial‐based spectral fitting model. The sensor shows a good performance in terms of its temperature measurement accuracy under high temperature of 673–1373 K and high pressure of 100–600 kPa condition in a tube furnace, which was lower than 4%. Moreover, three‐dimensional temperature distributions have been reconstructed via applying algebraic reconstruction technique at the test section after the combustion chamber of an aero engine model. The single‐point position temperature extracted from the algebraic reconstruction technique agrees well with that measured from the coherent anti‐stokes Raman scattering technique, where the relative error is within 5%. All the above results prove the reliability of our developed temperature sensor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.