Abstract

Lightweight and compact permanent magnet arrays (PMAs) are suitable for portable dedicated magnetic resonance imaging (MRI). It is worth exploring different PMA design possibilities and optimization methods with an adequate balance between weight, size, and performance, in addition to Halbach arrays and C-shaped/H-shaped magnets which are widely used. In this paper, the design and optimization of a sparse high-performance inward-outward ring-pair PMA consisting of magnet cuboids is presented for portable imaging of the brain. The design is lightweight (151kg) and compact (inner bore diameter: 270mm, outer diameter: 616mm, length: 480mm, 5-Gauss range: 1840×1840×2340mm3). The optimization framework is based on the genetic algorithm with a consideration of both field properties and simulated image quality. The resulting PMA design has an average field strength of 101.5 mT and a field pattern with a built-in linear readout gradient. Subtracting the best fit to the linear gradient target resulted in a residual deviation from the target field of 0.76mT and an average linear regression coefficient of 0.85 to the linear gradient. The required radiofrequency bandwidth is 6.9% within a field of view (FoV) with a diameter of 200mm and a length of 125mm. It has a magnetic field generation efficiency of 0.67mT/kg, which is high among the sparse PMAs that were designed for an FoV with a diameter of 200mm. The field can be used to supply gradients in one direction working with gradient coils in the other two directions, or can be rotated to encode signals for imaging with axial slice selection. The encoding capability of the designed PMA was examined through the simulated reconstructed images. The force experienced by each magnet in the design was calculated, and the feasibility of a physical implementation was confirmed. The design can offer an increased field strength, and thus, an increased signal-to-noise ratio. It has a longitudinal field direction that allows the application of technologies developed for solenoidal magnets. This proposed design can be a promising alternative to supplying the main and gradient fields in combination for dedicated portable MRI. Lastly, the design is resulted from a fast genetic algorithm-based optimization in which fast magnetic field calculation was applied and high design flexibility was feasible. Within optimization iterations, image quality metrics were used for the encoding field of a magnet configuration to guide the design of the magnet array.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.