Abstract

A reversed-phase HPLC method using acetonitrile-methanol-1 M perchloric acid-water (30:9:1:95, v/v) at a flow-rate of 1.5 ml/min on a μ-Bondapak C 18 column with UV detection at 254 nm was developed for the separation of primaquine, its major metabolite carboxyprimaquine and other metabolites such as N-acetyl-primaquine, 4-hydroxyprimaquine, 5-hydroxyprimaquine, 5-hydroxy-6-methoxyprimaquine, demethylprimaquine and 6-methoxyprimaquine, and also other antimalarials. The calibration graphs were linear in the range 0.025–100 μg/ml for primaquine and 4–100 μg/ml for carboxyprimaquine. The within-day and day-to-day coefficients of variation averaged 3.65 and 6.95%, respectively, for primaquine and 3.0 and 7.52%, respectively, for carboxyprimaquine in plasma. The extraction recoveries for primaquine and carboxyprimaquine were 89 and 83%, respectively. The mean carboxyprimaquine concentration was much higher in plasma and blood cells of Plasmodium vivax patients than that in plasma from healthy subjects. The carboxyprimaquine level was also higher in blood cells than plasma whereas the primaquine concentration was the same in both cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.