Abstract
Analytical conditions of prepurification extraction and HPLC separation were optimized for determination of urinary serotonin and tryptamine. Under optimal conditions, serotonin, tryptamine and an internal standard were extracted with 15% v/v n-propanol in diethyl ether from urine samples alkalized with a phosphate buffer (0.75 mol/L, pH 10.0), and then they were re-extracted into an HCl solution (0.1 mol/L). Purified indoleamines were simultaneously separated by reversed-phase ion-pair HPLC with native fluorescence detection. Urinary serotonin and tryptamine were selectively determined within about 45 min per sample for the whole procedure. Analytical recovery, reproducibility and detection sensitivity were satisfactory for pursuing time-dependent changes in indoleamine levels. Urinary excretion profiles of serotonin and tryptamine in subjects dosed with L-tryptophan were successfully analyzed by our method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.