Abstract

A simple, accurate, and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantification of Baclofen in rat plasma. The method demonstrated high degree of linearity (r2 = 0.9936) across a concentration range of 10-50 μg/mL. Precision, accuracy, limit of detection (LOD), limit of quantification (LOQ), and robustness were evaluated according to ICH guidelines. The LOD and LOQ were found to be 0.076197 and 0.23090 μg/mL, respectively. This method provides an efficient approach for Baclofen quantification in plasma, making it suitable for pharmacokinetic and bioavailability studies. The novelty of this study lies in its optimization for routine use in laboratories, ensuring reproducibility with minimal variations across different conditions and analysts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.