Abstract
This study evaluated the applicability of a high-frequency ultrasonic test to the inspection of the bonded interfaces between a divertor monoblock and a cooling pipe. This study prepared a tungsten block bonded with 1 mm of oxygen-free copper and 1.5 mm-thick CuCrZr plates, which simplifies one of the fundamental designs of a divertor: a tungsten monoblock bonded with a cooling pipe with a copper interlayer. The samples were fabricated using a high-temperature vacuum furnace for diffusion bonding. A high-frequency ultrasonic immersion test using a 30 MHz probe was performed from the CuCrZr surface to simulate inspecting the interface from inside the pipe. Ultrasonic images obtained by the test were consistent with the actual bonding condition revealed by sectioning the samples; whether a flaw exists on the interface between CuCrZr and the oxygen-free copper or that between the oxygen-free copper and tungsten was clearly distinguished. The results of this study also suggested the possibility of detecting the growth of crystal grains caused by improper bonding such as too high bonding temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.