In order to verify the strain-rate effects on the correlation between strain energy of metals and their cavitation-damage resistance, high-frequency fatigue tests at 14.2 kcs were conducted using a magnetostriction oscillator. Utilizing Morrow’s theory, it has been shown that fatigue at this frequency can be quantitatively represented if a 15 percent reduction in static strain-hardening factor is made. This result shows that the strain-rate effects are relatively small (for the metals investigated) when plastic-strain energy is used as a criterion. Another result revealed by this study is the influence of corrosion on high-frequency fatigue and cavitation-damage resistance. Present experiments show that fatigue strength can be reduced significantly for SAE 1020 steel in 3 percent NaCl solution even at high frequencies, thus confirming earlier speculations on this aspect.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.