Abstract

We report here an improved protocol for the preparation of full-length cDNA libraries that improves the previously reported method (Carninci, P., Kvam, K., Kitamura, A. et al. 1996, Genomics, 137, 327-336), that allows long cDNAs to be cloned more efficiently. One potential disadvantage of the original biotinylated CAP trapper protocol is the exposure of mRNA to chemical and enzymatic attacks during the biotinylation of the cap structure, before the first-strand cDNA synthesis (and selection of full-length cDNA by biotinylated cap). Here, we show that the biotinylation of the cap structure is very specific and effective even if biotinylation is performed on the mRNA/cDNA hybrid produced by the first-strand cDNA synthesis reaction. Consequently, mRNA remains protected from chemical and enzymatic degradation during the overnight biotinylation step, thus making it possible to select full-length cDNAs of longer average size. We herein report the efficiency and specificity of the new version of the protocol for cap structure biotinylation and capture of full-length cDNA.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.