Abstract
This study develops a delamination detection system by extending our previous approach for monitoring surface cracks in a large-scale composite structure. In the new system, numerous thin glass capillaries are embedded into a composite structure, and internal pressure in the built-in capillary sensors, based on comparative vacuum monitoring (CVM), is maintained as a vacuum. When delamination is induced, the capillary sensors located within the delaminated area are breached, and atmospheric air flows into the capillaries. The consequent pressure change within the capillaries is then converted into axial strain in a surface-mounted optical fiber through a transducing mechanism, which is connected to the capillaries. By monitoring the strain distribution along the optical fiber, it is possible to identify a transducing mechanism in which the pressure change occurred and thus to specify the location of the delamination. This study begins by establishing a novel sensor embedding/extracting method. The airflow characteristic in the capillary sensors is then comprehensively evaluated, determining the basic performance of the new system. The proposed detection technique is validated by taking a step-by-step approach, and finally the hierarchical fiber-optic delamination detection system is demonstrated. A further advance to be combined with a self-healing concept is also discussed.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have